CKJ5 1000A Contactor Three Poles Vertical Type AC Vacuum Contactor

    CKJ5 1000A Contactor Three Poles Vertical Type AC Vacuum Contactor

    CKJ5-1000A1250A1600A Vertical VacuumContactor Starters 1140VCKJ5 series vacuum contactor is suitable for AC 50hz, rated voltage up to 1140v,rated current up to 1600a power circuit, for long-distance connection anddisconnection of the circuit and frequent starting and control of AC motors, and issuitable for all kinds of protection, assembled into explosion-proof vacuumelectromagnetic starter.Advantages: good compatibility, stable and reliable performance, free maintenanceand long service life, is old-fashioned vacuum contactor is the ideal substitute ofproducts. Normal working and install...
  • shiriki:
  • Wasiliana nasi Uchunguzi wa Mtandaoni
  • Whatsapp:8613736779975

CKJ5-1000A1250A1600A Vertical VacuumContactor Starters 1140V

CKJ5 series vacuum contactor is suitable for AC 50hz, rated voltage up to 1140v,rated current up to 1600a power circuit, for long-distance connection anddisconnection of the circuit and frequent starting and control of AC motors, and issuitable for all kinds of protection, assembled into explosion-proof vacuumelectromagnetic starter.

Advantages: good compatibility, stable and reliable performance, free maintenanceand long service life, is old-fashioned vacuum contactor is the ideal substitute ofproducts.

 

Normal working and installation conditions of CKJ5 1000A 1250A1600A vertical vacuum contactor

1. Surrounding air temperature: -5°C~+40"C, the average value of which does not exceed +35'C within 24 hours;altitude of the installation site: not exceeding 2000m.

2. Atmospheric conditions: the relative humidity of the air at +40 'C does not exceed 50%; at lower temperaturescan be higher relative humidity, the average monthly low temperature of the wet month does not exceed +25 °Cthe average monthly relative humidity of the month does not exceed 90%, and take into account the condensationof the product due to the temperature change.

3. Pollution level: Class 3.

4. Installation category: Class ll.

5. lnstallation conditions: mounting surface and vertical inclination of not more than 15 ° .6. Shock and vibration: the low voltage vacuum contactor should be installed and used in places without signifcantshaking, shock and vibration.


Main circuit rated voltage

kV

1.14-1000

1.14-1250

1.14-1600

Main circuit rated current

A

1000

1250

1600

Main circuit making capacity

A/100 times

6000

6000

6000

Main circuit breaking capacity

A/10 times

4800

5000

5000

Limit breaking capacity

A/3 times

6000

6000

6000

Electrical life AC3

times

200000

Electrical life AC4

times

20000

Mechanical life time

times

1000000

Rated operating frequency AC3

times/h

100

Rated operating frequency AC4

times/h

120

Short-time operation

times/h

3000

Contact opening

mm

3±0.5

Over travel

mm

≥1.3

Lebo zinazohusiana:

UJUMBE MTANDAONI

Tafadhali jaza barua pepe halali
nambari ya uthibitishaji Haiwezi kuwa tupu

BIDHAA ZINAZOHUSIANA

Bado hakuna matokeo ya utafutaji!
Contact Us

Phone: +8613736779975

E-mail: sales@vcbbreaker.com

Address: 66 Punan Road, Yueqing Economic Development Zone, Zhejiang, China

Hakimiliki © 2025 Yangmei Kikundi cha Umeme Haki zote zimehifadhiwa

Ramani ya tovuti

Tovuti hii hutumia vidakuzi ili kuhakikisha unapata matumizi bora kwenye tovuti yetu.

Kubali kukataa